Magnetio-Matic "Dial-A-Field" Alinco Magnet Charger
This unit is capable of adjusting the magnetic field of Alnico magnets. It
was originally designed to be used to modify the field of HP/Agilent 5517
laser magnets so that their REF frequency could be set as desired. The
bare magnet, or magnet/tube assembly (with slight modifications) of 5501A/B
and 5517 (except for 5517A) fit inside the work coil.
Specifications:
- Magnet dimensions: up to 2.1" OD and 8" L.
- Range of resulting field:0 to 500+ G.
- Energy: Approximately 25 J max (2,000 uF capacitor charged to
160 V).
- Waveform: Near critically damped single pulse.
- Polarity: Reversing switch.
- Controls: Power, Strength, Fire
- Indicators: Energized (line on), Power (part of Strength knob),
Charging Level (2 yellow LEDs), Capacitor Voltage (red LED and meter).
- Input: 115 VAC.
The